 "name": "MedResin medical-grade resin data",
 "version": "2026-10-20",
 "generated": "2026-10-20",
 "count": 391,
 "url": "https://medresin.com/",
 "terms": "Free to use with attribution to MedResin.com and a link. Commercial use in AI products, APIs or resale requires a license: hello@medresin.com. See https://medresin.com/data",
 "notes": "Values as stated by the cited manufacturer source. Empty string = not stated by the source, not 'no'. Verify with the manufacturer before use.",
 "grades": [
  {
   "grade": "Lustran 348",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "ABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked). INEOS regulatory table (rev. August 2026, p.28) lists the Lustran 348 DMF as \"in progress\" (Novodur HD 15: DMF 18858; HD M203FC: 15885), so FDA master file is left blank (checked 2026-10-20).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-lustran-348"
  },
  {
   "grade": "Novodur HD 15",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "ABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-novodur-hd-15"
  },
  {
   "grade": "Novodur HD M203FC",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "ABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-novodur-hd-m203fc"
  },
  {
   "grade": "OPTIX CA-1000IG",
   "manufacturer": "Plaskolite",
   "resin_family": "Acrylic",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Plaskolite datasheet: USP Class VI; suitable for gamma or EtO sterilization (medical guide: dry EtO only; gamma yellowing is temporary).",
   "source_url": "https://plaskolite.com/docs/default-source/rds/pds283_oap_ca_1000_ig.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://plaskolite.com/docs/default-source/rds/pds283_oap_ca_1000_ig.pdf",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/plaskolite-optix-ca-1000ig"
  },
  {
   "grade": "Marlex 9012",
   "manufacturer": "Chevron Phillips Chemical",
   "resin_family": "HDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "CPChem PRO: meets USP <87>, <88> Class VI (70 °C) and <661.1>; FDA Type III DMF 1646.",
   "source_url": "https://www.cpchem.com/sites/default/files/2025-08/9012_PRO_FC_07182025_Rev_1.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.cpchem.com/sites/default/files/2021-08/TDS%20-%20Marlex%C2%AE%209012%20Polyethylene.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/chevron-phillips-chemical-marlex-9012"
  },
  {
   "grade": "Marlex 9018",
   "manufacturer": "Chevron Phillips Chemical",
   "resin_family": "HDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "CPChem PRO: meets USP <87>, <88> Class VI (70 °C) and <661.1>; FDA Type III DMF 1646.",
   "source_url": "https://www.cpchem.com/sites/default/files/2025-08/9018_PRO_FC_07182025_Rev_1.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.cpchem.com/sites/default/files/2021-08/TDS%20-%20Marlex%C2%AE%209018%20Polyethylene.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/chevron-phillips-chemical-marlex-9018"
  },
  {
   "grade": "Purell PE5307",
   "manufacturer": "LyondellBasell",
   "resin_family": "HDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pe5307"
  },
  {
   "grade": "Purell PE5618",
   "manufacturer": "LyondellBasell",
   "resin_family": "HDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pe5618"
  },
  {
   "grade": "Purell 1840H",
   "manufacturer": "LyondellBasell",
   "resin_family": "LDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-1840h"
  },
  {
   "grade": "Purell 3020D",
   "manufacturer": "LyondellBasell",
   "resin_family": "LDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-3020d"
  },
  {
   "grade": "Purell 3220D",
   "manufacturer": "LyondellBasell",
   "resin_family": "LDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-3220d"
  },
  {
   "grade": "Terlux HD 2802/2822",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked). Manufacturer brochure lists Terlux HD 2802 only; 2822 not confirmed.",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-terlux-hd-2802-2822"
  },
  {
   "grade": "Terlux HD 2812",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-terlux-hd-2812"
  },
  {
   "grade": "Clearblend 145",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-clearblend-145"
  },
  {
   "grade": "Clearblend 165",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-clearblend-165"
  },
  {
   "grade": "Zylar 631",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-zylar-631"
  },
  {
   "grade": "Zylar 960",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-zylar-960"
  },
  {
   "grade": "Ultradur PRO B4521",
   "manufacturer": "BASF",
   "resin_family": "PBT",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C: limited resistance; 134/143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultradur PRO steam 121 °C limited, gamma/e-beam and EtO full resistance, plasma limited.",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultradur-pro-b4521"
  },
  {
   "grade": "Apec 1745",
   "manufacturer": "Covestro",
   "resin_family": "PC (high-heat)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam up to 143 °C; Apec specimens kept comparatively good impact strength after 100 cycles at 120-125 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-apec-1745"
  },
  {
   "grade": "Apec 2045",
   "manufacturer": "Covestro",
   "resin_family": "PC (high-heat)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam up to 143 °C; Apec specimens kept comparatively good impact strength after 100 cycles at 120-125 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-apec-2045"
  },
  {
   "grade": "Makrolon 2458",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-2458"
  },
  {
   "grade": "Makrolon 2558",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-2558"
  },
  {
   "grade": "Makrolon Rx1805",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx1805"
  },
  {
   "grade": "Makrolon Rx2235",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2235"
  },
  {
   "grade": "Makrolon Rx2435",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2435"
  },
  {
   "grade": "Makrolon Rx2530",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2530"
  },
  {
   "grade": "Makrolon Rx3440",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx3440"
  },
  {
   "grade": "Makrolon M410 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m410-gf"
  },
  {
   "grade": "Bayblend M750",
   "manufacturer": "Covestro",
   "resin_family": "PC/ABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-bayblend-m750"
  },
  {
   "grade": "ZEONEX 690R",
   "manufacturer": "Zeon",
   "resin_family": "COP",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://zeonsmi.com/uploads/downloads/Medical-grade-overview-data-sheet_V2026_09_29.pdf",
   "alt_source_url": "https://www.zeonsmi.com/resources/downloads/",
   "datasheet_url": "https://zeonsmi.com/uploads/downloads/ZEONEX_690R_V2026_09_29.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/zeon-zeonex-690r"
  },
  {
   "grade": "ZEONEX 790R",
   "manufacturer": "Zeon",
   "resin_family": "COP",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://zeonsmi.com/uploads/downloads/Medical-grade-overview-data-sheet_V2026_09_29.pdf",
   "alt_source_url": "https://www.zeonsmi.com/resources/downloads/",
   "datasheet_url": "https://zeonsmi.com/uploads/downloads/ZEONEX_790R_V2026_09_29.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/zeon-zeonex-790r"
  },
  {
   "grade": "ZEONOR 1020R",
   "manufacturer": "Zeon",
   "resin_family": "COP",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://zeonsmi.com/uploads/downloads/Medical-grade-overview-data-sheet_V2026_09_29.pdf",
   "alt_source_url": "https://www.zeonsmi.com/resources/downloads/",
   "datasheet_url": "https://zeonsmi.com/uploads/downloads/ZEONOR_1020R_V2026_09_29.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/zeon-zeonor-1020r"
  },
  {
   "grade": "ZEONEX 5000",
   "manufacturer": "Zeon",
   "resin_family": "COP",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://zeonsmi.com/uploads/downloads/Medical-grade-overview-data-sheet_V2026_09_29.pdf",
   "alt_source_url": "https://www.zeonsmi.com/resources/downloads/",
   "datasheet_url": "https://zeonsmi.com/uploads/downloads/ZEONEX_5000_V2026_09_29.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/zeon-zeonex-5000"
  },
  {
   "grade": "Ultraform N2320 003 PRO AT",
   "manufacturer": "BASF",
   "resin_family": "POM",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance. USP Class VI and ISO 10993-5 cytotoxicity: yes; DMF 34139 (BASF table).",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "https://download.basf.com/p1/8a8082587fd4b608017fd64402e17397/en/ULTRAFORM%3Csup%3E%C2%AE%3Csup%3E_N2320_003_PRO_AT_Product_Data_Sheet_Europe_English.pdf?view=",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-n2320-003-pro-at"
  },
  {
   "grade": "Ultraform S1320 003 PRO AT",
   "manufacturer": "BASF",
   "resin_family": "POM",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance. USP Class VI and ISO 10993-5 cytotoxicity: yes; DMF 33419 (BASF table).",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-s1320-003-pro-at"
  },
  {
   "grade": "Ultraform S2320 003 PRO AT",
   "manufacturer": "BASF",
   "resin_family": "POM",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance.",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-s2320-003-pro-at"
  },
  {
   "grade": "Ultraform W2320 003 PRO AT",
   "manufacturer": "BASF",
   "resin_family": "POM",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance.",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-w2320-003-pro-at"
  },
  {
   "grade": "23M2A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-23m2a"
  },
  {
   "grade": "23R2A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-23r2a"
  },
  {
   "grade": "H0500HN",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-h0500hn"
  },
  {
   "grade": "13R9A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-13r9a"
  },
  {
   "grade": "23N10A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-23n10a"
  },
  {
   "grade": "11R12A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-11r12a"
  },
  {
   "grade": "P4C5N-046",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-p4c5n-046"
  },
  {
   "grade": "11M35V",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-11m35v"
  },
  {
   "grade": "13T25A",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-13t25a"
  },
  {
   "grade": "P5M6K-080",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-p5m6k-080"
  },
  {
   "grade": "P9M7R-056",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-p9m7r-056"
  },
  {
   "grade": "Purell HP6331",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-hp6331"
  },
  {
   "grade": "Purell PF511",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pf511"
  },
  {
   "grade": "Purell PF531",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pf531"
  },
  {
   "grade": "Purell RP491S",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-rp491s"
  },
  {
   "grade": "3740WR",
   "manufacturer": "TotalEnergies",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "good gamma radiation stability up to 50 kGy",
   "autoclave_cycles": "",
   "notes": "TotalEnergies TDS: recommended for injection-molded medical applications.",
   "source_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3740WR-US.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3740WR-US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/totalenergies-3740wr"
  },
  {
   "grade": "3847MR",
   "manufacturer": "TotalEnergies",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "TotalEnergies TDS: passed USP Class VI; resists typical gamma sterilization levels.",
   "source_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3847MR-US.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3847MR-US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/totalenergies-3847mr"
  },
  {
   "grade": "3944MR",
   "manufacturer": "TotalEnergies",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "TotalEnergies TDS: resists typical gamma sterilization levels; USP Class VI not stated on the TDS.",
   "source_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3944MR-US.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://polymers.totalenergies.com/sites/g/files/wompnd5016/files/site_collection_documents/Technical%20Datasheets/3944MR-US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/totalenergies-3944mr"
  },
  {
   "grade": "Ultrason E 2010",
   "manufacturer": "BASF",
   "resin_family": "PESU",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "noticeable property decline only above 2 MGy (Ultrason E)",
   "autoclave_cycles": "up to 100 superheated-steam cycles at 134 °C (avoid mechanical stress)",
   "notes": "BASF brochure: Ultrason S/E steam (134 °C) up to 100 cycles if mechanical stress is avoided; very resistant to gamma/beta/X-rays. BASF family used.",
   "source_url": "https://download.basf.com/p1/8a8082587fd4b608017fd654898f0d1e/en/Ultrason%3Csup%3E%C2%AE%3Csup%3E_E_S_P_%28PESU_PSU_PPSU%29_%E2%80%92_Product_Brochure_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultrason-e-2010"
  },
  {
   "grade": "Ultrason E 3010",
   "manufacturer": "BASF",
   "resin_family": "PESU",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "noticeable property decline only above 2 MGy (Ultrason E)",
   "autoclave_cycles": "up to 100 superheated-steam cycles at 134 °C (avoid mechanical stress)",
   "notes": "BASF brochure: Ultrason S/E steam (134 °C) up to 100 cycles if mechanical stress is avoided; very resistant to gamma/beta/X-rays. BASF family used.",
   "source_url": "https://download.basf.com/p1/8a8082587fd4b608017fd654898f0d1e/en/Ultrason%3Csup%3E%C2%AE%3Csup%3E_E_S_P_%28PESU_PSU_PPSU%29_%E2%80%92_Product_Brochure_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultrason-e-3010"
  },
  {
   "grade": "Ultrason S 2010",
   "manufacturer": "BASF",
   "resin_family": "PSU",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "up to 100 superheated-steam cycles at 134 °C (avoid mechanical stress)",
   "notes": "BASF brochure: Ultrason S/E steam (134 °C) up to 100 cycles if mechanical stress is avoided; very resistant to gamma/beta/X-rays.",
   "source_url": "https://download.basf.com/p1/8a8082587fd4b608017fd654898f0d1e/en/Ultrason%3Csup%3E%C2%AE%3Csup%3E_E_S_P_%28PESU_PSU_PPSU%29_%E2%80%92_Product_Brochure_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultrason-s-2010"
  },
  {
   "grade": "APEX 32043RV-NT1",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam.",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-32043rv-nt1"
  },
  {
   "grade": "APEX 33043RV-NT1",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam.",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-33043rv-nt1"
  },
  {
   "grade": "Styroflex 2G66",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "S-TPE",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-styroflex-2g66"
  },
  {
   "grade": "Luran HD 20 TR64000",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SAN",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Full Service HD package: USP Class VI, ISO 10993 (-4/-5), food contact statements and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-luran-hd-20-tr64000"
  },
  {
   "grade": "K-Resin KR01",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SBC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-k-resin-kr01"
  },
  {
   "grade": "Styrolux 656C",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SBC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-styrolux-656c"
  },
  {
   "grade": "NAS 21",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SMMA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-nas-21"
  },
  {
   "grade": "NAS 30",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SMMA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-nas-30"
  },
  {
   "grade": "Texin RxS285",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxs285"
  },
  {
   "grade": "Texin RxT50D",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt50d"
  },
  {
   "grade": "Texin RxT65D",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt65d"
  },
  {
   "grade": "Texin RxT70A",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt70a"
  },
  {
   "grade": "Texin RxT85A",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt85a"
  },
  {
   "grade": "Texin RxT90A",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx can be sterilized with EtO, gamma and e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt90a"
  },
  {
   "grade": "TOPAS 8007S-04",
   "manufacturer": "TOPAS Advanced Polymers",
   "resin_family": "COC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "TOPAS brochure: studied grades meet USP Class VI & ISO 10993; 8007 rated EtO + gamma, not steam. DMF/MAF numbers cited only by SpecialChem (secondary), removed.",
   "source_url": "https://topas.com/wp-content/uploads/2023/05/TOPAS-Medical-Brochure.pdf",
   "alt_source_url": "https://topas.com/wp-content/uploads/2023/05/TDS_8007S-04_e_US.pdf",
   "datasheet_url": "https://topas.com/wp-content/uploads/2023/05/TDS_8007S-04_e_US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/topas-advanced-polymers-topas-8007s-04"
  },
  {
   "grade": "TOPAS 6017S-04",
   "manufacturer": "TOPAS Advanced Polymers",
   "resin_family": "COC",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "TOPAS datasheet does not state compliance or sterilization; previous values came from SpecialChem (secondary) and were removed pending a TOPAS source.",
   "source_url": "https://topas.com/tech-center/datasheets/6017s-04/",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/topas-advanced-polymers-topas-6017s-04"
  },
  {
   "grade": "TOPAS 6013M-07",
   "manufacturer": "TOPAS Advanced Polymers",
   "resin_family": "COC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://topas.com/company/news/new-topas-6013m-07-blow-molding-injection-molding/",
   "alt_source_url": "",
   "datasheet_url": "https://topas.com/wp-content/uploads/2023/05/TDS-6013M-07_e_US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/topas-advanced-polymers-topas-6013m-07"
  },
  {
   "grade": "Radel R-5000",
   "manufacturer": "Syensqo (Solvay)",
   "resin_family": "PPSU",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.syensqo.com/en/brands/radel-ppsu/healthcare",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-16",
   "page": "https://medresin.com/grades/syensqo-solvay-radel-r-5000"
  },
  {
   "grade": "Zeniva ZA-600",
   "manufacturer": "Syensqo (Solvay)",
   "resin_family": "PEEK",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.syensqo.com/en/solutions-market/healthcare/medical-devices-equipment/implantable-devices",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-16",
   "page": "https://medresin.com/grades/syensqo-solvay-zeniva-za-600"
  },
  {
   "grade": "Silopren LSR 4060",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://dev.momentive.com/content/dam/momentive/global/docs/default-source/tds/silopren/silopren-lsr-4060.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4060"
  },
  {
   "grade": "Silopren LSR 4080",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://dev.momentive.com/content/dam/momentive/global/docs/default-source/tds/silopren/silopren-lsr-4080.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4080"
  },
  {
   "grade": "Silopren LSR 4660",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/Silopren%20LSR%204660.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4660"
  },
  {
   "grade": "VESTAMID Care ML16",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml16"
  },
  {
   "grade": "VESTAMID Care ML17",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml17"
  },
  {
   "grade": "VESTAMID Care ML18",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml18"
  },
  {
   "grade": "VESTAMID Care ML19",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml19"
  },
  {
   "grade": "VESTAMID Care ML21",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-50 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml21"
  },
  {
   "grade": "PEEK-OPTIMA (family)",
   "manufacturer": "Invibio (Victrex)",
   "resin_family": "PEEK",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Invibio fact sheet (current download on invibio.com, dated 8/2020): PEEK-OPTIMA polymers can be repeatedly sterilized using steam, EtO or gamma; biocompatibility is supported by comprehensive master files (type not stated). USP Class VI and ISO 10993 are not named in the fact sheet.",
   "source_url": "https://invibio.com/-/media/downloads/invibio/fact-sheets/peek-optima-polymers-fact-sheet_final-08-2020.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/invibio-victrex-peek-optima-family"
  },
  {
   "grade": "SILPURAN 6000/10 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600010-ab/p/000011067",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-10-a-b"
  },
  {
   "grade": "SILPURAN 6000/30 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600030-ab/p/000011069",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-30-a-b"
  },
  {
   "grade": "SILPURAN 6000/50 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600050-ab/p/000011071",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-50-a-b"
  },
  {
   "grade": "SILPURAN 6000/60 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600060-ab/p/000011072",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-60-a-b"
  },
  {
   "grade": "Pellethane 2363 Series",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "FDA master file removed 2026-10-20: no current public Lubrizol document states an MAF for this series (Lubrizol 2025 Medical Device Solutions guide 25-0004408 mentions only generic master-file support).",
   "source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-series"
  },
  {
   "grade": "Pellethane 2363-75D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization from Lubrizol family-level guidance: https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-75D.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/medical-device-tpu-product-guide.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-75D.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-75d"
  },
  {
   "grade": "Tecoflex (aliphatic series)",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/medical-device-tpu-product-guide.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-aliphatic-series"
  },
  {
   "grade": "Carbothane (aliphatic series)",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/medical-device-tpu-product-guide.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-aliphatic-series"
  },
  {
   "grade": "ULTEM HU1004",
   "manufacturer": "SABIC",
   "resin_family": "PEI blend",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC Material Finder (re-checked): steam, gamma, EtO and e-beam sterilizable; biocompatible (ISO 10993 or USP Class VI).",
   "source_url": "https://materialfinder.sabic-specialties.com/explore-applications/ultemhu1004",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1004",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu1004"
  },
  {
   "grade": "Veradel HC PESU",
   "manufacturer": "Syensqo (Solvay)",
   "resin_family": "PESU",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.syensqo.com/en/solutions-market/healthcare/medical-devices-equipment/implantable-devices/usages",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-16",
   "page": "https://medresin.com/grades/syensqo-solvay-veradel-hc-pesu"
  },
  {
   "grade": "Makrolon 2258",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-2258"
  },
  {
   "grade": "Makrolon Rx1452",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx1452"
  },
  {
   "grade": "Makrolon Rx1851",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx1851"
  },
  {
   "grade": "Makrolon 2658",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-2658"
  },
  {
   "grade": "Makrolon 2858",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-2858"
  },
  {
   "grade": "Makrolon 3158",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-3158"
  },
  {
   "grade": "Makrolon 3258",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-3258"
  },
  {
   "grade": "Makrolon 3638",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Covestro grade text: suitable for EtO, radiation and steam sterilization at 121 °C.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-3638"
  },
  {
   "grade": "Makrolon Rx2430",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2430"
  },
  {
   "grade": "Makrolon Rx2440",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2440"
  },
  {
   "grade": "Makrolon Rx2635",
   "manufacturer": "Covestro",
   "resin_family": "PC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C; Covestro says do not exceed 125 °C for Makrolon",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less). Radiation-stabilized grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-rx2635"
  },
  {
   "grade": "Makrolon M420 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m420-gf"
  },
  {
   "grade": "Makrolon M430 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m430-gf"
  },
  {
   "grade": "Makrolon M810 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m810-gf"
  },
  {
   "grade": "Makrolon M820 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m820-gf"
  },
  {
   "grade": "Makrolon M830 GF",
   "manufacturer": "Covestro",
   "resin_family": "PC/GF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m830-gf"
  },
  {
   "grade": "Makrolon M204 LF",
   "manufacturer": "Covestro",
   "resin_family": "PC (low friction)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "single sterilization cycle only (steam 121 °C)",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m204-lf"
  },
  {
   "grade": "Makrolon M402 LF",
   "manufacturer": "Covestro",
   "resin_family": "PC (low friction)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "single sterilization cycle only (steam 121 °C)",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m402-lf"
  },
  {
   "grade": "Makrolon M404 LF",
   "manufacturer": "Covestro",
   "resin_family": "PC (low friction)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "28 kGy assumed per sterilization; 10-20 sterilizations before appreciable strength loss (Makrolon/Apec, per Covestro)",
   "autoclave_cycles": "single sterilization cycle only (steam 121 °C)",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m404-lf"
  },
  {
   "grade": "Bayblend M850 XF",
   "manufacturer": "Covestro",
   "resin_family": "PC/ABS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Covestro portfolio statement (ISO 10993 and USP Class VI for contact of 30 days or less).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-bayblend-m850-xf"
  },
  {
   "grade": "Makroblend M525",
   "manufacturer": "Covestro",
   "resin_family": "PC/PBT",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Biocompatibility limited to contact with uncompromised skin (ISO 10993).",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makroblend-m525"
  },
  {
   "grade": "Makrolon M6011 FR",
   "manufacturer": "Covestro",
   "resin_family": "PC (flame retardant)",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam at 121 °C",
   "notes": "Flame retardant (UL94 V-0 at 1.5 mm). Biocompatibility limited to contact with uncompromised skin.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makrolon-m6011-fr"
  },
  {
   "grade": "Bayblend M301 FR",
   "manufacturer": "Covestro",
   "resin_family": "PC/ABS (flame retardant)",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Flame retardant. Biocompatibility limited to contact with uncompromised skin (ISO 10993). Sterilization not stated for this grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-bayblend-m301-fr"
  },
  {
   "grade": "Bayblend M303 FR",
   "manufacturer": "Covestro",
   "resin_family": "PC/ABS (flame retardant)",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Flame retardant. Biocompatibility limited to contact with uncompromised skin (ISO 10993). Sterilization not stated for this grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-bayblend-m303-fr"
  },
  {
   "grade": "Makroblend M4000 FR",
   "manufacturer": "Covestro",
   "resin_family": "PC/PBT (flame retardant)",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Flame retardant. Biocompatibility limited to contact with uncompromised skin (ISO 10993). Sterilization not stated for this grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makroblend-m4000-fr"
  },
  {
   "grade": "Makroblend M5005 FR",
   "manufacturer": "Covestro",
   "resin_family": "PC/PBT (flame retardant)",
   "usp_class_vi": "",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Flame retardant. Biocompatibility limited to contact with uncompromised skin (ISO 10993). Sterilization not stated for this grade.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-makroblend-m5005-fr"
  },
  {
   "grade": "Purell PD702",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pd702"
  },
  {
   "grade": "Purell HP6523",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-hp6523"
  },
  {
   "grade": "Purell EP494T",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP (impact copolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP status listed as pending by LYB.",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-ep494t"
  },
  {
   "grade": "Purell SR549M",
   "manufacturer": "LyondellBasell",
   "resin_family": "PP (random copolymer)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-sr549m"
  },
  {
   "grade": "Purell PE53003",
   "manufacturer": "LyondellBasell",
   "resin_family": "HDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pe53003"
  },
  {
   "grade": "Purell PE53003Z",
   "manufacturer": "LyondellBasell",
   "resin_family": "HDPE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://cdn.brandfolder.io/EZH48IU3/at/pv38vhjwthkb78rv8xm8tg2r/SM531_2026_May_OP_Purell_NA_Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lyondellbasell-purell-pe53003z"
  },
  {
   "grade": "Tecothane TT-1074A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1074a"
  },
  {
   "grade": "Tecothane TT-1085A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1085a"
  },
  {
   "grade": "Tecothane TT-1095A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1095a"
  },
  {
   "grade": "Tecothane TT-1055D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1055d"
  },
  {
   "grade": "Tecothane TT-1065D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1065d"
  },
  {
   "grade": "Tecothane TT-1069D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1069d"
  },
  {
   "grade": "Tecothane TT-1072D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1072d"
  },
  {
   "grade": "Tecothane TT-1075D-M",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecothane-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-tt-1075d-m"
  },
  {
   "grade": "Pellethane 2363-80A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-80A.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-80a"
  },
  {
   "grade": "Pellethane 2363-80AE",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-80AE.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-80ae"
  },
  {
   "grade": "Pellethane 5863-85A-R1",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-5863-85A-R1.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-5863-85a-r1"
  },
  {
   "grade": "Pellethane 5863-87A-R1",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-5863-87A-R1.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-5863-87a-r1"
  },
  {
   "grade": "Pellethane 2363-90A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-90A.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-90a"
  },
  {
   "grade": "Pellethane 2363-90AE",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-90AE.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-90ae"
  },
  {
   "grade": "Pellethane 2363-55D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-55D.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-55d"
  },
  {
   "grade": "Pellethane 2363-55DE",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-55DE.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-55de"
  },
  {
   "grade": "Pellethane 2363-65D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyether)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Lubrizol TDS: USP Class VI biocompatibility testing (USP XXII guidelines).",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-2363-65D.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-2363-65d"
  },
  {
   "grade": "Pellethane 5855-92A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyester)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Pellethane-5855-92A.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-5855-92a"
  },
  {
   "grade": "Pellethane 5855-70D-WF",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyester)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-pellethane-5855-70d-wf"
  },
  {
   "grade": "Isoplast 2510",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-isoplast-2510"
  },
  {
   "grade": "Isoplast 2530 R1",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-isoplast-2530-r1"
  },
  {
   "grade": "Isoplast 2531",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-isoplast-2531"
  },
  {
   "grade": "Isoplast 2540",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-isoplast-2540"
  },
  {
   "grade": "Tecoplast TP-470 Clear",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoplast-tp-470-clear"
  },
  {
   "grade": "Tecoplast OP-770 Opaque",
   "manufacturer": "Lubrizol",
   "resin_family": "Rigid TPU (aromatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoplast-op-770-opaque"
  },
  {
   "grade": "Carbothane PC-3575A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aliphatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-pc-3575a"
  },
  {
   "grade": "Carbothane PC-3585A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aliphatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-pc-3585a"
  },
  {
   "grade": "Carbothane PC-3595A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aliphatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-pc-3595a"
  },
  {
   "grade": "Carbothane PC-3555D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aliphatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-pc-3555d"
  },
  {
   "grade": "Carbothane PC-3572D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aliphatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-pc-3572d"
  },
  {
   "grade": "Carbothane AC-4075A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4075a"
  },
  {
   "grade": "Carbothane AC-4085A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4085a"
  },
  {
   "grade": "Carbothane AC-4095A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4095a"
  },
  {
   "grade": "Carbothane AC-4055D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4055d"
  },
  {
   "grade": "Carbothane AC-4065D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4065d"
  },
  {
   "grade": "Carbothane AC-4075D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polycarbonate)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Carbothane-TPU-Clear-Aromatic.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-carbothane-ac-4075d"
  },
  {
   "grade": "Tecoflex EG-80A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-80a"
  },
  {
   "grade": "Tecoflex EG-85A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-85a"
  },
  {
   "grade": "Tecoflex EG-93A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-93a"
  },
  {
   "grade": "Tecoflex EG-100A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-100a"
  },
  {
   "grade": "Tecoflex EG-60D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-60d"
  },
  {
   "grade": "Tecoflex EG-65D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-65d"
  },
  {
   "grade": "Tecoflex EG-68D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-68d"
  },
  {
   "grade": "Tecoflex EG-72D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-TPU-Clear.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-eg-72d"
  },
  {
   "grade": "Tecoflex MG-8020",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-mg-8020"
  },
  {
   "grade": "Tecoflex MG-8812",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-mg-8812"
  },
  {
   "grade": "Tecoflex SG-80A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-sg-80a"
  },
  {
   "grade": "Tecoflex SG-85A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-sg-85a"
  },
  {
   "grade": "Tecoflex SG-60D",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-sg-60d"
  },
  {
   "grade": "Tecophilic HP-93A-100",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-TPU-Extrusion-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-hp-93a-100"
  },
  {
   "grade": "Tecophilic HP-60D-20",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-TPU-Extrusion-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-hp-60d-20"
  },
  {
   "grade": "Tecophilic HP-60D-35",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-TPU-Extrusion-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-hp-60d-35"
  },
  {
   "grade": "Tecophilic HP-60D-60",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-TPU-Extrusion-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-hp-60d-60"
  },
  {
   "grade": "Tecophilic SP-80A-150",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-sp-80a-150"
  },
  {
   "grade": "Tecophilic SP-93A-100",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-sp-93a-100"
  },
  {
   "grade": "Tecophilic SP-60D-60",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (hydrophilic aliphatic)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecophilic-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecophilic-sp-60d-60"
  },
  {
   "grade": "Tecothane Soft AR-75A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyester)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Sterilization guidance is for Tecothane overall; Tecothane Soft is not listed separately.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-soft-ar-75a"
  },
  {
   "grade": "Tecothane Soft AR-85A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyester)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Sterilization guidance is for Tecothane overall; Tecothane Soft is not listed separately.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-soft-ar-85a"
  },
  {
   "grade": "Tecothane Soft AR-95A",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aromatic polyester)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy: may cause discoloration (performance not affected)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); gamma/e-beam may cause discoloration but performance is not affected; autoclave not recommended. Sterilization guidance is for Tecothane overall; Tecothane Soft is not listed separately.",
   "source_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Solutions/Technologies/PDF/25-0004408-MedicalDeviceSolutions-US-LTR-ENGLISH.pdf",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecothane-soft-ar-95a"
  },
  {
   "grade": "Hostaform MT 8U01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE8U01/941567ae/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-8u01"
  },
  {
   "grade": "Hostaform MT 12U01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE12U01/a56fb4e6/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-12u01"
  },
  {
   "grade": "Hostaform MT 12U03",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE12U03/d07a19cb/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-12u03"
  },
  {
   "grade": "Hostaform MT 24U01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM+MT24U01/816727f4/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-24u01"
  },
  {
   "grade": "Hostaform MT 8R02",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE8R02/9fd66c2d/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-8r02"
  },
  {
   "grade": "Hostaform MT 12R01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE12R01/fd2eb019/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-12r01"
  },
  {
   "grade": "Hostaform MT 8F01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE8F01/0fdf181c/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-8f01"
  },
  {
   "grade": "Hostaform MT 8F02",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Not found in Celanese's current datasheet listing on Material Data Center (checked 2026-10-17); it may be discontinued.",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-8f02"
  },
  {
   "grade": "Hostaform MT 24F01",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE24F01/6d538f6d/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-24f01"
  },
  {
   "grade": "Hostaform MT 8U05",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE8U05/6361fa65/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-8u05"
  },
  {
   "grade": "Hostaform MT SlideX 1203",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE+SlideX%C2%AE+1203/c58cc4cd/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-slidex-1203"
  },
  {
   "grade": "Hostaform MT SlideX 2404",
   "manufacturer": "Celanese",
   "resin_family": "POM",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Hostaform/Celanese/HOSTAFORM%C2%AE+MT%C2%AE+SlideX%C2%AE+2404/8305977b/2434",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-hostaform-mt-slidex-2404"
  },
  {
   "grade": "Celanex 2401MT",
   "manufacturer": "Celanese",
   "resin_family": "PBT",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Celanex/Celanese/CELANEX%C2%AE+2401MT/e7f5e114/2424",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-celanex-2401mt"
  },
  {
   "grade": "Celanex 2402MT",
   "manufacturer": "Celanese",
   "resin_family": "PBT",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Celanex/Celanese/CELANEX%C2%AE+2402MT/8e38042e/2424",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-celanex-2402mt"
  },
  {
   "grade": "Celanex 2404MT",
   "manufacturer": "Celanese",
   "resin_family": "PBT",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "no",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Celanex/Celanese/CELANEX%C2%AE+2404MT/200a2589/2424",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-celanex-2404mt"
  },
  {
   "grade": "Celanex 2405MT",
   "manufacturer": "Celanese",
   "resin_family": "PBT",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Celanex/Celanese/CELANEX%C2%AE+2405MT/85e9f333/2424",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-celanex-2405mt"
  },
  {
   "grade": "GUR 1020",
   "manufacturer": "Celanese",
   "resin_family": "UHMW-PE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Celanese's GUR product manual (2016) states USP Class VI and FDA Master Files for the medical grades but no ISO 10993 statement; no current grade datasheet with an ISO 10993 statement was found (checked 2026-10-17).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-gur-1020"
  },
  {
   "grade": "GUR 1050",
   "manufacturer": "Celanese",
   "resin_family": "UHMW-PE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Celanese's GUR product manual (2016) states USP Class VI and FDA Master Files for the medical grades but no ISO 10993 statement; no current grade datasheet with an ISO 10993 statement was found (checked 2026-10-17).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-gur-1050"
  },
  {
   "grade": "GUR 1020-E",
   "manufacturer": "Celanese",
   "resin_family": "UHMW-PE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Celanese's GUR product manual (2016) states USP Class VI and FDA Master Files for the medical grades but no ISO 10993 statement; no current grade datasheet with an ISO 10993 statement was found (checked 2026-10-17).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-gur-1020-e"
  },
  {
   "grade": "GUR 1050-E",
   "manufacturer": "Celanese",
   "resin_family": "UHMW-PE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Celanese's GUR product manual (2016) states USP Class VI and FDA Master Files for the medical grades but no ISO 10993 statement; no current grade datasheet with an ISO 10993 statement was found (checked 2026-10-17).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-gur-1050-e"
  },
  {
   "grade": "GUR 1001",
   "manufacturer": "Celanese",
   "resin_family": "UHMW-PE",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Source dated 2018: Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy). It lists cytotoxicity testing for the grade; its only ISO 10993 mention is a general service-package line (\"USP Class VI / ISO 10993, etc.\") that doesn't name the grade or its product line, so the ISO 10993 column is left blank. Celanese's GUR product manual (2016) states USP Class VI and FDA Master Files for the medical grades but no ISO 10993 statement; no current grade datasheet with an ISO 10993 statement was found (checked 2026-10-17). No DMF/MAF listed for this grade.",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-gur-1001"
  },
  {
   "grade": "Fortron MT 9140L4",
   "manufacturer": "Celanese",
   "resin_family": "PPS (40% GF)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Fortron/Celanese/FORTRON%C2%AE+MT9140L4/8a09bfb8/2431",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-fortron-mt-9140l4"
  },
  {
   "grade": "Fortron MT 9140L6",
   "manufacturer": "Celanese",
   "resin_family": "PPS (40% GF)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Fortron/Celanese/FORTRON%C2%AE+MT9140L6/9830b5a8/2431",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-fortron-mt-9140l6"
  },
  {
   "grade": "Vectra MT 1300",
   "manufacturer": "Celanese",
   "resin_family": "LCP",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Vectra/Celanese/VECTRA+MT1300/bc2f2eba/2442",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-vectra-mt-1300"
  },
  {
   "grade": "Vectra MT 1310",
   "manufacturer": "Celanese",
   "resin_family": "LCP (30% GF)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Vectra/Celanese/VECTRA+MT1310/9536bf65/2442",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-vectra-mt-1310"
  },
  {
   "grade": "Vectra MT 4310",
   "manufacturer": "Celanese",
   "resin_family": "LCP (30% GF)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Vectra/Celanese/VECTRA%C2%AE+MT%C2%AE4310/f95ce26e/2442",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-vectra-mt-4310"
  },
  {
   "grade": "Vectra MT 4350",
   "manufacturer": "Celanese",
   "resin_family": "LCP (40% mineral)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Vectra/Celanese/VECTRA+MT4350/46e57144/2442",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-vectra-mt-4350"
  },
  {
   "grade": "Vectra MT 1335",
   "manufacturer": "Celanese",
   "resin_family": "LCP (glass/PTFE)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF, MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "steam 121/134 °C rated \"possible\"",
   "notes": "Current Celanese grade datasheet (Material Data Center, checked 2026-10-17) states biocompatibility in tests corresponding to USP Class VI/ISO 10993 and lists DMF and MAF. Sterilization ratings are from the Celanese brochure \"Medical and Pharmaceutical Materials\" (MED-016, printed 2018, third-party hosted copy).",
   "source_url": "https://edm.industrysourcing.com/edm/2021/conf/vemd2021/celanese_brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.materialdatacenter.com/ms/en/Vectra/Celanese/VECTRA%C2%AE+MT%C2%AE1335/c0468737/2442",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/celanese-vectra-mt-1335"
  },
  {
   "grade": "VESTAMID Care ML67",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml67"
  },
  {
   "grade": "VESTAMID Care ML94",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml94"
  },
  {
   "grade": "VESTAMID Care ML24",
   "manufacturer": "Evonik",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-50 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-ml24"
  },
  {
   "grade": "VESTAMID Care MLGB30",
   "manufacturer": "Evonik",
   "resin_family": "PA12 (glass beads)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-100 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-mlgb30"
  },
  {
   "grade": "VESTAMID Care ME26",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "limited",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "",
   "notes": "Evonik: ME26 does not meet the ISO 10993-5 cytotoxicity requirement (53% viability) and is slightly hemolytic.",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me26"
  },
  {
   "grade": "VESTAMID Care ME40",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "<5 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me40"
  },
  {
   "grade": "VESTAMID Care ME47",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me47"
  },
  {
   "grade": "VESTAMID Care ME55",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-50 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me55"
  },
  {
   "grade": "VESTAMID Care ME62",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-50 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me62"
  },
  {
   "grade": "VESTAMID Care ME71",
   "manufacturer": "Evonik",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "25-50 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestamid-care-me71"
  },
  {
   "grade": "TROGAMID Care MX73",
   "manufacturer": "Evonik",
   "resin_family": "PA (transparent microcrystalline)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-trogamid-care-mx73"
  },
  {
   "grade": "TROGAMID Care MX97",
   "manufacturer": "Evonik",
   "resin_family": "PA (transparent microcrystalline)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "5-25 steam sterilization cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-trogamid-care-mx97"
  },
  {
   "grade": "VESTAKEEP Care M20 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "> 500 autoclave cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestakeep-care-m20-g"
  },
  {
   "grade": "VESTAKEEP Care M33 G-HP",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "> 500 autoclave cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestakeep-care-m33-g-hp"
  },
  {
   "grade": "VESTAKEEP Care M40 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "> 500 autoclave cycles",
   "notes": "",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/evonik-vestakeep-care-m40-g"
  },
  {
   "grade": "Tritan MX711",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "tested at 50 kGy (minimal color shift; Eastman)",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070154",
   "alt_source_url": "https://www.eastman.com/content/dam/eastman/corporate/en/literature/s/spmbs1164.pdf",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070154",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-tritan-mx711"
  },
  {
   "grade": "Tritan MX731",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070461",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070461",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-tritan-mx731"
  },
  {
   "grade": "Tritan MX811",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71072160",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71072160",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-tritan-mx811"
  },
  {
   "grade": "Tritan MX710",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman TDS lists good color stability upon gamma and EtO sterilization; no biocompatibility statement on the TDS.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070148",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070148",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-tritan-mx710"
  },
  {
   "grade": "Eastar MN006",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71064561",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71064561",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-eastar-mn006"
  },
  {
   "grade": "Eastar MN005",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71055564",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71055564",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-eastar-mn005"
  },
  {
   "grade": "Eastar MN052",
   "manufacturer": "Eastman",
   "resin_family": "Polyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71059437",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71059437",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-eastar-mn052"
  },
  {
   "grade": "Eastar MN058",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman TDS: \"Meets ISO 10993 and/or USP Class VI biocompatibility requirements\" (which one is not specified, so both left blank). TDS key attribute: gamma and e-beam color stability (listed as gamma). EtO and autoclave not stated.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71068566",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71068566",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-eastar-mn058"
  },
  {
   "grade": "Eastar MN211",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman TDS: \"Meets ISO 10993 and/or USP Class VI biocompatibility requirements\" (which one is not specified, so both left blank). TDS key attribute: gamma and e-beam color stability (listed as gamma). EtO and autoclave not stated.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71017000",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71017000",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/eastman-eastar-mn211"
  },
  {
   "grade": "Medalist MD-36165",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-36165"
  },
  {
   "grade": "Medalist MD-53253",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53253"
  },
  {
   "grade": "Medalist MD-53263",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53263"
  },
  {
   "grade": "Medalist MD-53268",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53268"
  },
  {
   "grade": "Medalist MD-53273",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53273"
  },
  {
   "grade": "Medalist MD-53278",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53278"
  },
  {
   "grade": "Medalist MD-53283",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53283"
  },
  {
   "grade": "Medalist MD-53288",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53288"
  },
  {
   "grade": "Medalist MD-53293",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-53293"
  },
  {
   "grade": "Medalist MD-12337",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12337"
  },
  {
   "grade": "Medalist MD-12342",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12342"
  },
  {
   "grade": "Medalist MD-12352",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12352"
  },
  {
   "grade": "Medalist MD-12362",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Datasheet lists autoclave and EtO sterilizable. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.teknorapex.com/datasheet/pdf/en/287329.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12362"
  },
  {
   "grade": "Medalist MD-12368",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Datasheet lists autoclave and EtO sterilizable. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.teknorapex.com/datasheet/pdf/en/211311.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12368"
  },
  {
   "grade": "Medalist MD-12372",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12372"
  },
  {
   "grade": "Medalist MD-12382",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (medical tubing)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: series \"Biocompatible, ISO 10993-5 compliant\" (cytotoxicity only, so ISO 10993 column left blank); sterilization by e-beam, gamma and EtO. Coded cytotoxicity-only 2026-10-20 per Teknor Apex Medalist tubing sell sheet (\"Biocompatible, ISO 10993-5 compliant\").",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/teknor-pardot-assets-/Medalist___Medical_Elastomers_for_Medical_Tubing.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-12382"
  },
  {
   "grade": "Medalist MD-91760",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (biopharma tubing)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: MD-90000 series meets USP Class VI and ISO 10993-5 (cytotoxicity; ISO column left blank); sterilizable by EO, gamma, e-beam, X-ray and autoclaving.",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/en-us/pdf/technical-literature/Medalist_SellSheet_FINAL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-91760"
  },
  {
   "grade": "Medalist MD-91970",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (biopharma tubing)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: MD-90000 series meets USP Class VI and ISO 10993-5 (cytotoxicity; ISO column left blank); sterilizable by EO, gamma, e-beam, X-ray and autoclaving.",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/en-us/pdf/technical-literature/Medalist_SellSheet_FINAL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-91970"
  },
  {
   "grade": "Medalist MD-96267",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (biopharma tubing)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: MD-90000 series meets USP Class VI and ISO 10993-5 (cytotoxicity; ISO column left blank); sterilizable by EO, gamma, e-beam, X-ray and autoclaving.",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/en-us/pdf/technical-literature/Medalist_SellSheet_FINAL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-96267"
  },
  {
   "grade": "Medalist MD-92260",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (biopharma tubing)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: MD-90000 series meets USP Class VI and ISO 10993-5 (cytotoxicity; ISO column left blank); sterilizable by EO, gamma, e-beam, X-ray and autoclaving.",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/en-us/pdf/technical-literature/Medalist_SellSheet_FINAL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-92260"
  },
  {
   "grade": "Texin RxT80A",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx biocompatible TPU; ISO 10993 and USP Class VI per portfolio statement; sterilize with EtO, gamma or e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt80a"
  },
  {
   "grade": "Texin RxT76D",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx biocompatible TPU; ISO 10993 and USP Class VI per portfolio statement; sterilize with EtO, gamma or e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxt76d"
  },
  {
   "grade": "Texin RxS292",
   "manufacturer": "Covestro",
   "resin_family": "TPU",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Covestro: Texin Rx biocompatible TPU; ISO 10993 and USP Class VI per portfolio statement; sterilize with EtO, gamma or e-beam; do not steam autoclave.",
   "source_url": "https://solutions.covestro.com/-/media/covestro/solution-center/story/brochures/covestro_healthcare-reference-guide_2025_new.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/covestro-texin-rxs292"
  },
  {
   "grade": "23R2B",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-23r2b"
  },
  {
   "grade": "12G50M",
   "manufacturer": "INVISTA",
   "resin_family": "PP",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INVISTA: biocompatibility results incl. USP <88> Class VI and ISO 10993-5 (cytotoxicity) for all MedSelect grades; \"Radiation\" sterilization listed as gamma.",
   "source_url": "https://invista-pp.com/InvistaPolypropylene/media/PolypropyleneGeneral/25-INV-Polypropylene-Medical-Brochure-V4.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/invista-12g50m"
  },
  {
   "grade": "NAS 90",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SMMA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-nas-90"
  },
  {
   "grade": "Zylar 245",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-zylar-245"
  },
  {
   "grade": "Zylar 550",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-zylar-550"
  },
  {
   "grade": "Zylar 650",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "MBS",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-zylar-650"
  },
  {
   "grade": "Styroflex 4G80",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "S-TPE",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-styroflex-4g80"
  },
  {
   "grade": "Styrolux 3G46",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SBC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-styrolux-3g46"
  },
  {
   "grade": "Styrolux 684D",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SBC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-styrolux-684d"
  },
  {
   "grade": "K-Resin KR03/KR05/DK11",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "SBC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution Essential HD package: USP Class VI, ISO 10993 compliance and DMF can be provided. Sterilization table: gamma, e-beam, EtO, NO2 (steam not ticked).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-k-resin-kr03-kr05-dk11"
  },
  {
   "grade": "Luran S MED 797S SPF30",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "ASA",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution sterilization table lists Luran S Med for gamma, e-beam, EtO and NO2. INEOS regulatory table (rev. August 2026, p.31): biocompatibility tests ISO 10993-5 (cytotoxicity) and ISO 10993-10 (hypersensitivity); USP Class VI and DMF not listed (checked 2026-10-20).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-luran-s-med-797s-spf30"
  },
  {
   "grade": "Luran S MED 797S FC",
   "manufacturer": "INEOS Styrolution",
   "resin_family": "ASA",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "INEOS Styrolution sterilization table lists Luran S Med for gamma, e-beam, EtO and NO2. INEOS regulatory table (rev. August 2026, p.31): biocompatibility tests ISO 10993-5 (cytotoxicity) and ISO 10993-10 (hypersensitivity); USP Class VI and DMF not listed (checked 2026-10-20).",
   "source_url": "https://www.ineos.com/contentassets/b97fc78f6a874895bf6506c5a8d97477/brochure_healthcare_global-emea_revaugust2026.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/ineos-styrolution-luran-s-med-797s-fc"
  },
  {
   "grade": "Ultraform S2320 003 PRO TR AT",
   "manufacturer": "BASF",
   "resin_family": "POM (tribologically modified)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "DMF",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance. BASF brochure p.11 compliance table: USP Class VI yes, cytotoxicity (ISO 10993-5) yes, DMF 34209 (checked 2026-10-20).",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-s2320-003-pro-tr-at"
  },
  {
   "grade": "Ultraform W2320 003 PRO TR AT",
   "manufacturer": "BASF",
   "resin_family": "POM (tribologically modified)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "limited",
   "eto": "yes",
   "autoclave": "limited",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "121 °C and 134 °C: limited resistance; 143 °C: no resistance (depends on conditions, duration and number of cycles)",
   "notes": "BASF sterilization table: Ultraform PRO steam limited, gamma/e-beam limited, EtO and plasma full resistance. BASF brochure p.11 compliance table shows \"–\" for USP Class VI, cytotoxicity and DMF for this TR grade (checked 2026-10-20), so biocompatibility is left blank.",
   "source_url": "https://download.basf.com/p1/8a8081c57fd4b609018021fe1bcc1c95/en/Ultraform%C2%AE_PRO_%28POM%29_and_Ultradur%C2%AE_PRO_%28PBT%29_-_Engineering_Plastics_for_Medical_Solutions_Brochure_English.pdf?view=",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/basf-ultraform-w2320-003-pro-tr-at"
  },
  {
   "grade": "Delrin SC631",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-sc631"
  },
  {
   "grade": "Delrin SC655",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-sc655"
  },
  {
   "grade": "Delrin RASC655",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-rasc655"
  },
  {
   "grade": "Delrin SC690",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles. PC690 variant: FDA DMF available.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-sc690"
  },
  {
   "grade": "Delrin SC698",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-sc698"
  },
  {
   "grade": "Delrin RASC698",
   "manufacturer": "Delrin (formerly DuPont)",
   "resin_family": "POM (homopolymer)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "\"a number of repeat autoclave cycles\" (not quantified)",
   "notes": "Delrin healthcare brochure: SC grades tested against relevant parts of ISO 10993 (-5, -11) and selected parts of USP Class VI (so both columns left blank); compatible with EtO and a number of repeat autoclave cycles.",
   "source_url": "https://www.delrin.com/wp-content/uploads/2024/02/Delrin-Healthcare-Brochure-NA-RevFNL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/delrin-formerly-dupont-delrin-rasc698"
  },
  {
   "grade": "TECAPEEK MT natural",
   "manufacturer": "Ensinger",
   "resin_family": "PEEK (stock shapes)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Ensinger: stock shapes tested to ISO 10993 and USP Class VI; resistant to repeated steam autoclaving; very good resistance to high-energy radiation (listed as gamma). Stock shapes, not molding resin.",
   "source_url": "https://www.ensingerplastics.com/en/shapes/medical-peek-tecapeek-mt-natural",
   "alt_source_url": "",
   "datasheet_url": "https://www.ensingerplastics.com/en/shapes/medical-peek-tecapeek-mt-natural",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/ensinger-tecapeek-mt-natural"
  },
  {
   "grade": "ULTEM HU1000",
   "manufacturer": "SABIC",
   "resin_family": "PEI",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: may offer steam, hydrogen peroxide, gamma, EtO, UV-C and e-beam resistance for repeated sterilization cycles.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1000",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1000",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu1000"
  },
  {
   "grade": "ULTEM HU1010",
   "manufacturer": "SABIC",
   "resin_family": "PEI",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: may offer steam, hydrogen peroxide, gamma, EtO, UV-C and e-beam resistance for repeated sterilization cycles.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1010",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1010",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu1010"
  },
  {
   "grade": "ULTEM HU2300",
   "manufacturer": "SABIC",
   "resin_family": "PEI (30% GF)",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: may offer steam, hydrogen peroxide, gamma, EtO, UV-C and e-beam resistance for repeated sterilization cycles.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2300",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2300",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu2300"
  },
  {
   "grade": "ULTEM HU1100",
   "manufacturer": "SABIC",
   "resin_family": "PEI",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: steam, gamma, EtO and e-beam sterilizable.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1100",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1100",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu1100"
  },
  {
   "grade": "ULTEM HU2100",
   "manufacturer": "SABIC",
   "resin_family": "PEI (10% GF)",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: steam, gamma, EtO and e-beam sterilizable.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2100",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2100",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu2100"
  },
  {
   "grade": "ULTEM HU2200",
   "manufacturer": "SABIC",
   "resin_family": "PEI (20% GF)",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: steam, gamma, EtO and e-beam sterilizable.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2200",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2200",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu2200"
  },
  {
   "grade": "LEXAN HPX4",
   "manufacturer": "SABIC",
   "resin_family": "PC copolymer",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: EtO and steam sterilizable; improved autoclavability.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx4",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx4",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-lexan-hpx4"
  },
  {
   "grade": "LEXAN HPX8R",
   "manufacturer": "SABIC",
   "resin_family": "PC copolymer",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: EtO sterilizable; contains mold release.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx8r",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx8r",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-lexan-hpx8r"
  },
  {
   "grade": "LEXAN HPX8REU",
   "manufacturer": "SABIC",
   "resin_family": "PC copolymer",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: EtO sterilizable; contains mold release (Europe).",
   "source_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx8reu",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/lexan-copolymer-hpx8reu",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-lexan-hpx8reu"
  },
  {
   "grade": "CYCOLOY HCX1640",
   "manufacturer": "SABIC",
   "resin_family": "PC/ABS",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: biocompatible grade for medical devices and pharmaceutical applications (standard not named); sterilization not stated.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/cycoloy-non-fr-resin-hcx1640",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/cycoloy-non-fr-resin-hcx1640",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-cycoloy-hcx1640"
  },
  {
   "grade": "TOPAS 6015S-04",
   "manufacturer": "TOPAS Advanced Polymers",
   "resin_family": "COC",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "hot steam 121, 134 and 143 °C: + (base type 6015)",
   "notes": "Sterilization from the TOPAS medical brochure table for the base type (6015); the grade datasheet does not state medical compliance. TOPAS states studied COC grades meet USP Class VI and ISO 10993 but does not list which grades, so those columns are blank.",
   "source_url": "https://topas.com/wp-content/uploads/2023/05/TOPAS-Medical-Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://topas.com/wp-content/uploads/2023/05/TDS_6015S-04_english-units.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/topas-advanced-polymers-topas-6015s-04"
  },
  {
   "grade": "TOPAS 5013S-04",
   "manufacturer": "TOPAS Advanced Polymers",
   "resin_family": "COC",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Sterilization from the TOPAS medical brochure table for the base type (5013); the grade datasheet does not state medical compliance. TOPAS states studied COC grades meet USP Class VI and ISO 10993 but does not list which grades, so those columns are blank.",
   "source_url": "https://topas.com/wp-content/uploads/2023/05/TOPAS-Medical-Brochure.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://topas.com/wp-content/uploads/2023/04/TDS-5013S-04_e_US.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/topas-advanced-polymers-topas-5013s-04"
  },
  {
   "grade": "VICTREX PC (family)",
   "manufacturer": "Victrex",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Victrex: VICTREX PC meets USP Class VI and USP <661> for non-implantable pharmaceutical contact applications. Individual grades and sterilization not listed on the page.",
   "source_url": "https://www.victrex.com/en/pc",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-19",
   "page": "https://medresin.com/grades/victrex-victrex-pc-family"
  },
  {
   "grade": "Radel R-5100",
   "manufacturer": "Syensqo (Solvay)",
   "resin_family": "PPSU",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "Over 1,000 steam cycles without significant loss of properties or appearance (Radel PPSU)",
   "notes": "Radel PPSU healthcare page: ISO 10993 tested, limited exposure (<24 h); compatible with steam, EtO, gamma and VHP. R-5100 listed in Syensqo healthcare TDS library.",
   "source_url": "https://www.syensqo.com/en/brands/radel-ppsu/healthcare",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-16",
   "page": "https://medresin.com/grades/syensqo-solvay-radel-r-5100"
  },
  {
   "grade": "Udel P-1700",
   "manufacturer": "Syensqo (Solvay)",
   "resin_family": "PSU",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Udel FAQ: good resistance to steam, EtO, gamma, plasma and chemical sterilization (lower than Radel PPSU). Biopharma page: Udel PSU tested to USP Class VI before and after gamma.",
   "source_url": "https://www.syensqo.com/en/brands/udel-psu/faq",
   "alt_source_url": "https://www.syensqo.com/en/solutions-market/healthcare/medical-devices-equipment/biopharma-processing",
   "datasheet_url": "",
   "last_verified": "2026-10-16",
   "page": "https://medresin.com/grades/syensqo-solvay-udel-p-1700"
  },
  {
   "grade": "Pebax 1074 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-1074-sa-01-med"
  },
  {
   "grade": "Pebax 2533 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-2533-sa-01-med"
  },
  {
   "grade": "Pebax 3533 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-3533-sa-01-med"
  },
  {
   "grade": "Pebax 4033 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-4033-sa-01-med"
  },
  {
   "grade": "Pebax 4533 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-4533-sa-01-med"
  },
  {
   "grade": "Pebax 5533 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-5533-sa-01-med"
  },
  {
   "grade": "Pebax 6333 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-6333-sa-01-med"
  },
  {
   "grade": "Pebax 7033 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-7033-sa-01-med"
  },
  {
   "grade": "Pebax 7233 SA 01 MED",
   "manufacturer": "Arkema",
   "resin_family": "PEBA",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "USP Class VI per Arkema Pebax regulatory table. All Pebax MED grades tested for ISO 10993-4 and -5 and are gamma, steam and ETO sterilizable (Arkema).",
   "source_url": "https://hpp.arkema.com/en/product-families/pebax-elastomer-family/regulatory-compliance/",
   "alt_source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/catherters-and-mediacl-tubing/",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-pebax-7233-sa-01-med"
  },
  {
   "grade": "Kynar 720 MED",
   "manufacturer": "Arkema",
   "resin_family": "PVDF",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "TDS: resistant to gamma, steam and ETO sterilization; USP Class VI and ISO 10993-4/-5 compliance letters on request.",
   "source_url": "https://hpp.arkema.com/en/products/product/f/flup_hpp_Kynar/p/kynar-720-med/",
   "alt_source_url": "",
   "datasheet_url": "https://hpp.arkema.com/assets/arkema/TDS_KYNAR%C2%AE%20720%20MED_en_WW.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-kynar-720-med"
  },
  {
   "grade": "Bormed DM55pharm",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 009146",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-dm55pharm"
  },
  {
   "grade": "Bormed HD800CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 020240",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-hd800cf"
  },
  {
   "grade": "Bormed HD850MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 017929",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-hd850mo"
  },
  {
   "grade": "Bormed HD810MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 009040",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Radiation package; Borealis states it was specially developed for gamma irradiation. US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/Brochure_BormedSolutionsHealthcare_032025.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-hd810mo"
  },
  {
   "grade": "Bormed HF840MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 009040",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-hf840mo"
  },
  {
   "grade": "Bormed HG820MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027799",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-hg820mo"
  },
  {
   "grade": "Bormed RB801CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 028484",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rb801cf"
  },
  {
   "grade": "Bormed RD804CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 028486",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rd804cf"
  },
  {
   "grade": "Bormed RD808CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 028487",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rd808cf"
  },
  {
   "grade": "Bormed RD834CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 031866",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rd834cf"
  },
  {
   "grade": "Bormed RE816CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 028485",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-re816cf"
  },
  {
   "grade": "Bormed RF825MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 031607",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rf825mo"
  },
  {
   "grade": "Bormed RF830MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 031609",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Radiation package; Borealis states it was specially developed for gamma irradiation. US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/Brochure_BormedSolutionsHealthcare_032025.pdf",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rf830mo"
  },
  {
   "grade": "Bormed RG835MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 031608",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rg835mo"
  },
  {
   "grade": "Bormed RJ880MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027840",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-rj880mo"
  },
  {
   "grade": "Bormed BJ868MO",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 033438",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-bj868mo"
  },
  {
   "grade": "Bormed SC820CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 020243",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-sc820cf"
  },
  {
   "grade": "Bormed SC876CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027916",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-sc876cf"
  },
  {
   "grade": "Bormed TD109CF",
   "manufacturer": "Borealis",
   "resin_family": "PP",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 024931",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-td109cf"
  },
  {
   "grade": "Bormed HE2581-PH",
   "manufacturer": "Borealis",
   "resin_family": "HDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027656",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-he2581-ph"
  },
  {
   "grade": "Bormed HE7541-PH",
   "manufacturer": "Borealis",
   "resin_family": "HDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027654",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-he7541-ph"
  },
  {
   "grade": "Bormed HE9621-PH",
   "manufacturer": "Borealis",
   "resin_family": "HDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 029149",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-he9621-ph"
  },
  {
   "grade": "Bormed LE6607-PH",
   "manufacturer": "Borealis",
   "resin_family": "LDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 008124/027108",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-le6607-ph"
  },
  {
   "grade": "Bormed LE6609-PH",
   "manufacturer": "Borealis",
   "resin_family": "LDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 017927/028752",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-le6609-ph"
  },
  {
   "grade": "Bormed LE6600-PH",
   "manufacturer": "Borealis",
   "resin_family": "LDPE",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 027587",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-le6600-ph"
  },
  {
   "grade": "Bormed PL8830-PH",
   "manufacturer": "Borealis",
   "resin_family": "Plastomer",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "DMF 033070",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "US DMF number per Borealis Bormed summary data sheet; pharmacopeia/ISO 10993 status per grade medical statement.",
   "source_url": "https://www.borealisgroup.com/storage/Industries/Healthcare-literature/SummaryDataSheet_Healthcare_062025.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/borealis-bormed-pl8830-ph"
  },
  {
   "grade": "NuSil MED-4950",
   "manufacturer": "NuSil (Avantor)",
   "resin_family": "Silicone",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Restricted: not for implantation >29 days. Data sheet lists only cytotoxicity testing (USP <87> / ISO 10993-5, pass), so the ISO 10993 column is left blank under MedResin's rule; FDA Master File filed.",
   "source_url": "https://nusil.avantorsciences.com/nusil/en/product/MED-4950/liquid-silicone-rubber",
   "alt_source_url": "",
   "datasheet_url": "https://digitalassets.avantorsciences.com/adaptivemedia/rendition?clid=SAPDAM&id=021948162de963f56096e10c117d3356b7260d61&prid=original&vid=a46ef6128bbd50a43bcc15853e8f8c404bcadce7",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/nusil-avantor-nusil-med-4950"
  },
  {
   "grade": "NuSil MED-6015",
   "manufacturer": "NuSil (Avantor)",
   "resin_family": "Silicone",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Restricted: not for implantation >29 days. Data sheet lists only cytotoxicity testing (USP <87> / ISO 10993-5, pass), so the ISO 10993 column is left blank under MedResin's rule; FDA Master File filed.",
   "source_url": "https://digitalassets.avantorsciences.com/adaptivemedia/rendition?clid=SAPDAM&id=b7ea5de6768acc836fcadd86c904c0e75d243cf3&prid=original&vid=63281615773810b401b5f22bf5253c36d3a5127f",
   "alt_source_url": "",
   "datasheet_url": "https://digitalassets.avantorsciences.com/adaptivemedia/rendition?clid=SAPDAM&id=b7ea5de6768acc836fcadd86c904c0e75d243cf3&prid=original&vid=63281615773810b401b5f22bf5253c36d3a5127f",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/nusil-avantor-nusil-med-6015"
  },
  {
   "grade": "ULTEM HU2310",
   "manufacturer": "SABIC",
   "resin_family": "PEI (30% GF)",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "yes",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: may offer steam, hydrogen peroxide, gamma, EtO, UV-C and e-beam resistance for repeated sterilization cycles.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2310",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu2310",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu2310"
  },
  {
   "grade": "ULTEM HU1110",
   "manufacturer": "SABIC",
   "resin_family": "PEI",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "SABIC: \"biocompatible (ISO 10993 or USP Class VI)\" - feature list names ISO 10993, so USP column left blank. Healthcare management of change applies. SABIC: steam, gamma, EtO and e-beam sterilizable.",
   "source_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1110",
   "alt_source_url": "",
   "datasheet_url": "https://materialfinder.sabic-specialties.com/material/ultem-resin-hu1110",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/sabic-ultem-hu1110"
  },
  {
   "grade": "VESTAKEEP i2 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037927.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037927.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i2-g"
  },
  {
   "grade": "VESTAKEEP i2 UFP10",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52046294.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52046294.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i2-ufp10"
  },
  {
   "grade": "VESTAKEEP i4 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037926.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037926.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i4-g"
  },
  {
   "grade": "VESTAKEEP i4 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037896.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037896.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i4-r"
  },
  {
   "grade": "VESTAKEEP i4 PL",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038596.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038596.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i4-pl"
  },
  {
   "grade": "VESTAKEEP i5 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037971.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037971.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i5-g"
  },
  {
   "grade": "VESTAKEEP i5 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037970.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037970.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-i5-r"
  },
  {
   "grade": "VESTAKEEP iC4506 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK (6% BaSO4)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038043.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038043.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-ic4506-g"
  },
  {
   "grade": "VESTAKEEP iC4506 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK (6% BaSO4)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038066.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038066.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-ic4506-r"
  },
  {
   "grade": "VESTAKEEP iC4520 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK (20% BaSO4)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MAF",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI (implant grade). Evonik biomaterials brochure (V3, 2025-11): Evonik holds FDA master access files (MAF) for VESTAKEEP Implant grade resins and stock shapes. Sterilization: brochure cites stability studies (steam, gamma, x-ray, e-beam) without per-grade ratings, so sterilization columns left blank.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038909.html",
   "alt_source_url": "https://products.evonik.com/assets/52/23/Online_brochure_medical_biomaterials_EU_V3_5c_251106_SD_EN_Asset_3745223.pdf",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038909.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-ic4520-g"
  },
  {
   "grade": "VESTAKEEP D4 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038769.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038769.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-d4-g"
  },
  {
   "grade": "VESTAKEEP D4 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038772.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038772.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-d4-r"
  },
  {
   "grade": "VESTAKEEP DC4420 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038770.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038770.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4420-g"
  },
  {
   "grade": "VESTAKEEP DC4420 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52037893.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52037893.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4420-r"
  },
  {
   "grade": "VESTAKEEP DC4450 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038771.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038771.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4450-g"
  },
  {
   "grade": "VESTAKEEP DC4450 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038773.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038773.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4450-r"
  },
  {
   "grade": "VESTAKEEP DC4470 G",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038937.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038937.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4470-g"
  },
  {
   "grade": "VESTAKEEP DC4470 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Evonik grade page: biocompatibility tested following ISO 10993-1 recommendations for permanent mucous membrane contact (dental grade). USP Class VI from Evonik quality-and-approvals table (Dental-Grade column, family-level). Sterilization not stated per grade.",
   "source_url": "https://www.evonik.com/en/products/hp/pr_52038952.html",
   "alt_source_url": "https://www.evonik.com/en/markets/market_1345345/vestakeep-peek-for-medical-devices/quality-and-approvals.html",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038952.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-dc4470-r"
  },
  {
   "grade": "VESTAKEEP Care M40 R",
   "manufacturer": "Evonik",
   "resin_family": "PEEK",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "up to 50 kGy (all Evonik Care grades)",
   "autoclave_cycles": "> 500 autoclave cycles",
   "notes": "Rod stock; shares the M40 G / M40PL / M40 R column in the Evonik Medical Care brochure. Evonik grade page: tested following ISO 10993-1 (up to 30 days body contact); fulfills USP <88> Class VI.",
   "source_url": "https://products.evonik.com/assets/34/33/Evonik_Medical_Care_brochure_1124_EN_243433.pdf",
   "alt_source_url": "",
   "datasheet_url": "https://www.evonik.com/en/products/hp/pr_52038776.html",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/evonik-vestakeep-care-m40-r"
  },
  {
   "grade": "SILPURAN 6000/05 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600005-ab/p/000011066",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-05-a-b"
  },
  {
   "grade": "SILPURAN 6000/20 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600020-ab/p/000011068",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-20-a-b"
  },
  {
   "grade": "SILPURAN 6000/40 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600040-ab/p/000011070",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-40-a-b"
  },
  {
   "grade": "SILPURAN 6000/70 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-600070-ab/p/000011073",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6000-70-a-b"
  },
  {
   "grade": "SILPURAN 6600/40 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-660040-ab/p/000011077",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6600-40-a-b"
  },
  {
   "grade": "SILPURAN 6600/50 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-660050-ab/p/000011078",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6600-50-a-b"
  },
  {
   "grade": "SILPURAN 6600/60 A/B",
   "manufacturer": "Wacker",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "MF (type not stated)",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "",
   "source_url": "https://www.wacker.com/h/en-us/silicone-rubber/liquid-silicone-rubber-lsr/silpuran-660060-ab/p/000011079",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-6600-60-a-b"
  },
  {
   "grade": "SILPURAN 2420 A/B",
   "manufacturer": "Wacker",
   "resin_family": "Silicone",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "RTV-2 addition-curing silicone. Wacker: biocompatible, certificates of compatibility with USP Class VI and ISO 10993 available on request.",
   "source_url": "https://www.wacker.com/h/en-us/c/silpuran-2420-ab/p/000011060",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/wacker-silpuran-2420-a-b"
  },
  {
   "grade": "Silopren LSR 4030",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4030.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4030"
  },
  {
   "grade": "Silopren LSR 4040",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4040.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4040"
  },
  {
   "grade": "Silopren LSR 4050",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4050.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4050"
  },
  {
   "grade": "Silopren LSR 4070",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4070.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4070"
  },
  {
   "grade": "Silopren LSR 4640",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4640.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4640"
  },
  {
   "grade": "Silopren LSR 4670",
   "manufacturer": "Momentive",
   "resin_family": "LSR",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Momentive TDS: biocompatible USP Class VI and ISO 10993 (parts 3, 4, 5, 6, 10, 11); sterilizable with EtO, steam and gamma. Regulatory section: tests were run on \"a representative sample of an analogous product\" (USP Class VI, max. 29 days tissue contact) (checked 2026-10-20).",
   "source_url": "https://www.momentive.com/content/dam/momentive/en-us/products/tds/silopren/silopren-lsr-4670.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/momentive-silopren-lsr-4670"
  },
  {
   "grade": "Rilsan BMNO MED",
   "manufacturer": "Arkema",
   "resin_family": "PA11",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsanbmnomed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-bmno-med"
  },
  {
   "grade": "Rilsan BESNO MED",
   "manufacturer": "Arkema",
   "resin_family": "PA11",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsanbesnomed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-besno-med"
  },
  {
   "grade": "Rilsan BESVO A MED",
   "manufacturer": "Arkema",
   "resin_family": "PA11",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsanbesvoamed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-besvo-a-med"
  },
  {
   "grade": "Rilsan 8020",
   "manufacturer": "Arkema",
   "resin_family": "PA (translucent copolyamide)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsan8020",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-8020"
  },
  {
   "grade": "Rilsan Clear G850 Rnew MED",
   "manufacturer": "Arkema",
   "resin_family": "PA11 (transparent)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsanclearg850rnewmed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-clear-g850-rnew-med"
  },
  {
   "grade": "Rilsan Clear G170 MED",
   "manufacturer": "Arkema",
   "resin_family": "PA12 (transparent)",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsanclearg170med",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsan-clear-g170-med"
  },
  {
   "grade": "Rilsamid AMNO MED",
   "manufacturer": "Arkema",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsamidamnomed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsamid-amno-med"
  },
  {
   "grade": "Rilsamid AESNO MED",
   "manufacturer": "Arkema",
   "resin_family": "PA12",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Arkema healthcare page: all products tested for ISO 10993-4 and -5 and USP Class VI (compliance letters on request); range is gamma, steam and ETO sterilizable. Listed in the Arkema MED grade list.",
   "source_url": "https://hpp.arkema.com/en/markets-and-applications/healthcare/healthcare-material-solutions/",
   "alt_source_url": "",
   "datasheet_url": "https://mypolymer.materialdatacenter.com/pds/en/si/rilsamidaesnomed",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/arkema-rilsamid-aesno-med"
  },
  {
   "grade": "Tritan MX730",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070516",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71070516",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/eastman-tritan-mx730"
  },
  {
   "grade": "Tritan MX810",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman: tested for FDA/ISO 10993 and USP Class VI biological evaluation after gamma and EtO sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71072159",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71072159",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/eastman-tritan-mx810"
  },
  {
   "grade": "Tritan MXF121",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman TDS: passed FDA/ISO 10993 testing for cytotoxicity, skin sensitization and intracutaneous reactivity. USP Class VI and sterilization not stated. Opaque; contains vegetable-based mold release.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71097008",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71097008",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/eastman-tritan-mxf121"
  },
  {
   "grade": "Eastar MN210",
   "manufacturer": "Eastman",
   "resin_family": "Copolyester",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Eastman TDS: \"meets ISO 10993 and/or USP Class VI biocompatibility requirement\" (which one is not specified, so both left blank). TDS key attribute: suitable for gamma and e-beam irradiation and ethylene oxide sterilization.",
   "source_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71015997",
   "alt_source_url": "",
   "datasheet_url": "https://productcatalog.eastman.com/tds/ProdDatasheet.aspx?product=71015997",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/eastman-eastar-mn210"
  },
  {
   "grade": "APEX 32033RN-NT1",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam. Series (Shore A 50-90).",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-32033rn-nt1"
  },
  {
   "grade": "APEX 33022RV-NT",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam. Series (Shore A 50-90).",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-33022rv-nt"
  },
  {
   "grade": "APEX 33033RV-NT1",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam. Series (Shore A 50-90).",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-33033rv-nt1"
  },
  {
   "grade": "APEX 33042RN-NT",
   "manufacturer": "Teknor Apex",
   "resin_family": "PVC",
   "usp_class_vi": "yes",
   "iso_10993": "yes",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex medical PVC page (family-level): \"Biocompatibility backed by USP Class VI & ISO 10993 testing\", including ISO 10993-5 cytotoxicity test data; holds color after gamma and e-beam. Series (Shore A 50-90).",
   "source_url": "https://www.teknorapex.com/en-us/teknor-apexs-extensive-product-portfolio-of-vinyl-thermoplastic-elastomers-nylon-and-colorants/vinyl/flexible-pvc-compounds/apex-flexible-pvc/apex-flexible-pvc-medical",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-apex-33042rn-nt"
  },
  {
   "grade": "Medalist MD-91255",
   "manufacturer": "Teknor Apex",
   "resin_family": "TPE (biopharma tubing)",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "cytotoxicity only",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "yes",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Teknor Apex: MD-90000 series meets USP Class VI and ISO 10993-5 (cytotoxicity; ISO column left blank); sterilizable by EO, gamma, e-beam, X-ray and autoclaving.",
   "source_url": "https://www.teknorapex.com/content/dam/teknorapex/en-us/pdf/technical-literature/Medalist_SellSheet_FINAL.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/teknor-apex-medalist-md-91255"
  },
  {
   "grade": "Tecoflex SG-93A-G",
   "manufacturer": "Lubrizol",
   "resin_family": "TPU (aliphatic polyether)",
   "usp_class_vi": "",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "no",
   "vhp": "yes",
   "gamma_dose_limit": "25 and 50 kGy recommended (single cycle tested)",
   "autoclave_cycles": "",
   "notes": "Sterilization per Lubrizol family-level guidance (single cycle tested); dry heat and autoclave not recommended.",
   "source_url": "https://www.lubrizol.com/solutions/products/tecoflex",
   "alt_source_url": "https://media.lubrizol.com/-/media/project/lubrizol-corporation/lubrizol/master-site/health/documents/literature/proper-sterilization-methods-for-medical-grade-thermoplastic-polyurethane-tpu-sterilization.pdf",
   "datasheet_url": "https://media.lubrizol.com/-/media/Project/Lubrizol-Corporation/Lubrizol/Master-Site/Health/Documents/TDS/Tecoflex-Solution-Grade.pdf",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/lubrizol-tecoflex-sg-93a-g"
  },
  {
   "grade": "OPTIX CA-927 G",
   "manufacturer": "Plaskolite",
   "resin_family": "Acrylic",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Plaskolite OPTIX medical guide: OPTIX Medical Grade Polymers are USP Class VI; resistant to gamma or (dry) ethylene oxide sterilization; wet EtO not recommended.",
   "source_url": "https://plaskolite.com/docs/default-source/bro/bro072_oap_medical.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/plaskolite-optix-ca-927-g"
  },
  {
   "grade": "OPTIX CA-927 GHF",
   "manufacturer": "Plaskolite",
   "resin_family": "Acrylic",
   "usp_class_vi": "yes",
   "iso_10993": "",
   "iso_10993_partial": "",
   "fda_mf": "",
   "gamma": "yes",
   "eto": "yes",
   "autoclave": "",
   "vhp": "",
   "gamma_dose_limit": "",
   "autoclave_cycles": "",
   "notes": "Plaskolite OPTIX medical guide: OPTIX Medical Grade Polymers are USP Class VI; resistant to gamma or (dry) ethylene oxide sterilization; wet EtO not recommended.",
   "source_url": "https://plaskolite.com/docs/default-source/bro/bro072_oap_medical.pdf",
   "alt_source_url": "",
   "datasheet_url": "",
   "last_verified": "2026-10-20",
   "page": "https://medresin.com/grades/plaskolite-optix-ca-927-ghf"
  }
 ]
}